Ravel Electronic PVT LTD Brand Logo Ravel Electronic PVT LTD Brand Logo Ravel Electronic PVT LTD Brand Logo
Toll Free No : 1800 1200 72835  +91 44 4204 0204  sales@ravelfire.com
Navigation
  • Home
  • About Us
  • Products
    • Addressable System
      • Multi Loop System
      • Single Loop Control System
    • Conventional Fire Systems
      • Panels
      • Detectors
      • Manual Activating Devices
      • Notification Devices
      • Networking Devices
      • Softwares
    • Gas Suppression System
      • Panels
      • Manual Activating Devices
      • Networking Devices
    • Public Address System
      • Main Consoles
      • Expanders
      • Amplifier for PA System
      • Speakers
    • Fireman Telephone System
      • Main Consoles
      • Fireman Jack
      • Handset
  • Tech Support
    • Escalation Matrix
  • Downloads
    • Datasheet
    • Credentials
    • Certifications
  • Media
    • Press Release
    • Blogs
    • News
  • Career
  • Contact

Revac Nx

Home Products PA System or Public Address System Main Consoles Revac Nx

ekonics-2014

Features

  • Operates on 220VAC 50 Hz, Main switch mode power supply.
  • Standby backup 24VDC battery.
  • CE approved.
  • 19″, Rack mountable.
  • System ON, Power fault, Common Fault indications.
  • Membrane Keypad for user friendly operation.
  • Inbuilt amplifier maximum 125 / 250 watts can accommodate in a console.
  • It can be integrated with any third party FACP.
  • Additional Amplifier can expand up to 250W.
  • One push to talk Microphone provided for announcement.
  • Zone Wise (Speaker line) Selection facility with LED indication.
  • All loud speaker lines are supervised.
  • Volume level indicator.
  • Voice / Alarm / Allcall / DVA / MIC selection facility
  • Programmable Mode (Alarm, Mic, Music, DVA) Selection facility.
  • 100V audio output for Speaker.
  • Fault Relay output for actuators.
  • Alarm activated on automatically announcing mode.
  • Compatible with RE-900 Series via RS 485 Communication.
  • Voice recording option available.
  • DVD Input Facility using 3.5mm jack.
  • Zone expansion in Multiples of 16, upto 128 Zone.
  • Tech Specifications
  • Downloads
  • Certificates
  • Tools
  • Specification

     

    Power Supply    
    Primary Power : 220VAC ± 10%, 50 Hz.
    Standby Power : 24VDC
    Charging Circuit

       
    Charging Voltage : 28 V ±0.2V Nominal
    Charging Current : 1.2A (Max.).
    Operating Temperature : 0 – 49° C/32-120° F.
    Relative Humidity : 93 ± 2% RH (non-condensing) at 32 ±2° C/90 ±3° F.
    Relay contact rating : 28 V ±0.2V Nominal : 2 Amps @ 30VDC , 0.5 Amps @ 125VAC.
    DC Output : 24 VDC @ Max 3A
    Audio

       
    audio output : 100V
    Max Wattage : Built-in 125W / 250W ; 500W Max.
    Audio Input : Inbuilt MIC, DVA & Alarm tone
    MIC Type : Hand mobile
    Communication Interface : RS-485
    Dimensions(3U) : (484 W X 134 H X 325 D)mm

    Compatible Devices

    Model Description
    RE-900 Series Fire Alarm Control Panel
    Any FACP Fire Alarm Control Panel
    RE-LS10W PA Wall Speaker
    RE-LS10C PA Ceiling Speaker
    RE-032XP 17-32 Zone PA Expander
    RE-048XP 33-48 Zone PA Expander
    RE-064XP 49-64 Zone PA Expander
    RE-080XP 65- 80 Zone PA Expander
    RE-096XP 81-96 Zone PA Expander
    RE-112XP 97-112 Zone PA Expander
    RE-128XP 113-128 Zone PA Expander

    Ordering Information

    Models Watts Description
    REVAC Nx 125W 1-16 Zone PA Main Console
    REVAC Nx 250W 1-16 Zone PA Main Console
    • Data Sheet

  • Addressable Fire Alarm System
    • Multi Loop System
      • Panels
      • Detectors
      • Modules
      • Manual Activating Devices
      • Notification Devices
      • Networking Devices
      • Softwares
    • Single Loop Control System
      • Panels
      • Detectors
      • Modules
      • Manual Activating Device
      • Notification Devices
  • Conventional Fire Alarm Systems
    • Panels
    • Detectors
    • Manual Activating Devices
    • Notification Devices
    • Networking Devices
    • Softwares
  • Gas Suppression System
    • Panels
    • Manual Activating Devices
    • Networking Devices
  • PA System or Public Address System
    • Main Consoles
    • Expanders
    • Amplifier for PA System
    • Speakers
  • Fireman Telephone System
    • Main Consoles
    • Fireman Jack
    • Handset
  • Emergency Signage

News & Events

We will be present at intersec Dubai 2024
Visit our stand at Intersec 2024, taking place from 16th to 18th January 2024 at the Dubai World Trade Centre ...
We will be present at intersec saudi arabia
Visit our Stall @ Stall no A36, Hall No.4 \r\n03rd – 05th October 2023 Intersec 2023, Riyadh International Con...

Credentials

credentials

 

Quick Links

  • CO Detector Suppliers | Sounder Cum Strobe | RE 326Series | RE 386-NG | GSM Auto Dailer | Soft connect | Gas Leak Detector | Input / Output Module | Loop Powered Sounder | Multi Sensor Detector | UL Listed Fire Alarm Panels | Fire Alarm System | Notification Devices | Fire Alarm Control Panel | Smoke Alarm Detector | Multi Loop System | Heat Detector | Manual Activating Devices | Conventional Fire System | Beam Detectors | Single Loop Control System | Quality Policy
  • 2025 © Ravel Electronics Pvt. Ltd.,

    Quick Enquiry

    Quick Enquiry