Ravel Electronic PVT LTD Brand Logo Ravel Electronic PVT LTD Brand Logo Ravel Electronic PVT LTD Brand Logo
Toll Free No : 1800 1200 72835  +91 44 4204 0204  sales@ravelfire.com
Navigation
  • Home
  • About Us
  • Products
    • Addressable System
      • Multi Loop System
      • Single Loop Control System
    • Conventional Fire Systems
      • Panels
      • Detectors
      • Manual Activating Devices
      • Notification Devices
      • Networking Devices
      • Softwares
    • Gas Suppression System
      • Panels
      • Manual Activating Devices
      • Networking Devices
    • Public Address System
      • Main Consoles
      • Expanders
      • Amplifier for PA System
      • Speakers
    • Fireman Telephone System
      • Main Consoles
      • Fireman Jack
      • Handset
  • Tech Support
    • Escalation Matrix
  • Downloads
    • Datasheet
    • Credentials
    • Certifications
  • Media
    • Press Release
    • Blogs
    • News
  • Career
  • Contact

RE-9032 RP

Home Products Conventional Fire Alarm Systems Panels RE-9032 RP

re-9032rp

Features

  • 20 X 4 Dot Matrix LCD display.
  • Alphanumeric keypads.
  • RS 485 Communication for Network Repeater.
  • System ON, AC ON, Battery ON, Charger ON indications.
  • Lamp test facility.
  • Maximum 16 panels including repeater can be connected in a Single Network via RS-485.
  • Repeater Panel can monitor the status of RE-900 series panels via RS-485 Network communication.
  • User can Disable / Enable the Zone of Fire Alarm Control Panel Connected in network.
  • Special Features
  • Tech Specifications
  • Downloads
  • Certificates
  • Tools
    • Ravel Indian Manufacturer, International standard.
    • Operates on RS-485 communication.
    • Repeats all the parameters of the main FACP.
  • Electrical Specification

    AC Power :
    120-220 VAC,60/ 50 Hz

    Battery (Lead Acid only)
    Charging Current: Constant Voltage – 27.6v @ 0.5A (Max.).
    24V D.C (2 Nos of 12v, 7Ah (Max.) Sealed Lead acid battery)
    System Quiescent Current: 70mA

    Operating Condition
    Operating Temperature : 0 – 49° C / 32-120° F.
    Relative Humidity 93 ± 2% RH (non-condensing) at 32 ±2° C / 90 ± 3° F.

    Notification Appliance Circuits (Sounder Circuit)
    Operating Nominal Voltage: 24 VDC
    Sounder (NAC) output: 0.5A
    End-Of-Line Resistor: 4.7K, 1/4watt

    Potential Free Relay Contact
    Type : Form C
    No of Relays : 1
    Relay Contact Rating: 2 Amps @ 30 VDC,
    0.5 Amps @125 VAC,
    Battery (Lead Acid only)
    Charging Current: Constant Voltage – 27.6v @ 0.5A (Max.).
    24V D.C (2 Nos of 12v, 7Ah (Max.) Sealed Lead acid battery)
    System Quiescent Current: 70mA

    Mechanical Specification

    Dimensions : (350W X 300H X 100D)
    Color : White
    Construction : 18 Gauge (1.22mm) CRCA sheet with powder-coated Finish
    IP Rating : IP50
    Cable Entry : 11xø19mm Knockout in top of the cabinet

    Compatible Devices

    Models Description
    RE-900 series Fire Alarm Control Panel

    Ordering Information

    Model Description
    Up to 32 Zones RE- 9032RP
    Up to 128 Zones RE- 9128RP
    Up to 256 Zones RE-9256RP

    NOTE:
    RE-9XXXRP →RE-900RP Series Repeater Panel
    XXX → 32Zone , 128Zone, 256Zone

    • RE – 9032RP
  • Addressable Fire Alarm System
    • Multi Loop System
      • Panels
      • Detectors
      • Modules
      • Manual Activating Devices
      • Notification Devices
      • Networking Devices
      • Softwares
    • Single Loop Control System
      • Panels
      • Detectors
      • Modules
      • Manual Activating Device
      • Notification Devices
  • Conventional Fire Alarm Systems
    • Panels
    • Detectors
    • Manual Activating Devices
    • Notification Devices
    • Networking Devices
    • Softwares
  • Gas Suppression System
    • Panels
    • Manual Activating Devices
    • Networking Devices
  • PA System or Public Address System
    • Main Consoles
    • Expanders
    • Amplifier for PA System
    • Speakers
  • Fireman Telephone System
    • Main Consoles
    • Fireman Jack
    • Handset
  • Emergency Signage

News & Events

We will be present at intersec Dubai 2024
Visit our stand at Intersec 2024, taking place from 16th to 18th January 2024 at the Dubai World Trade Centre ...
We will be present at intersec saudi arabia
Visit our Stall @ Stall no A36, Hall No.4 \r\n03rd – 05th October 2023 Intersec 2023, Riyadh International Con...

Credentials

credentials

 

Quick Links

  • CO Detector Suppliers | Sounder Cum Strobe | RE 326Series | RE 386-NG | GSM Auto Dailer | Soft connect | Gas Leak Detector | Input / Output Module | Loop Powered Sounder | Multi Sensor Detector | UL Listed Fire Alarm Panels | Fire Alarm System | Notification Devices | Fire Alarm Control Panel | Smoke Alarm Detector | Multi Loop System | Heat Detector | Manual Activating Devices | Conventional Fire System | Beam Detectors | Single Loop Control System | Quality Policy
  • 2025 © Ravel Electronics Pvt. Ltd.,

    Quick Enquiry

    Quick Enquiry