Ravel Electronic PVT LTD Brand Logo Ravel Electronic PVT LTD Brand Logo Ravel Electronic PVT LTD Brand Logo
Toll Free No : 1800 1200 72835  +91 44 4204 0204  sales@ravelfire.com
Navigation
  • Home
  • About Us
  • Products
    • Addressable System
      • Multi Loop System
      • Single Loop Control System
    • Conventional Fire Systems
      • Panels
      • Detectors
      • Manual Activating Devices
      • Notification Devices
      • Networking Devices
      • Softwares
    • Gas Suppression System
      • Panels
      • Manual Activating Devices
      • Networking Devices
    • Public Address System
      • Main Consoles
      • Expanders
      • Amplifier for PA System
      • Speakers
    • Fireman Telephone System
      • Main Consoles
      • Fireman Jack
      • Handset
  • Tech Support
    • Escalation Matrix
  • Downloads
    • Datasheet
    • Credentials
    • Certifications
  • Media
    • Press Release
    • Blogs
    • News
  • Career
  • Contact

RE-2558

Home Products Conventional Fire Alarm Systems Panels RE-2558

Overview

    The microprocessor based UL listed 8 Zone conventional fire alarm control panel, the system has 16 X 2 LCDcharacter, 8 zones detection circuit,3 common potential free contacts &2 common NAC sounder output, inbuilt Rs-485 for repeater connectivity, wall/ceiling mounted, Switch mode power supply- SMPS & Battery polarity & Deep discharge protection.
    RE-2558 fire alarm control panel is designed with unique protocol to be used for small & medium establishments, Schools, hospitals, hotels, banks, residential / commercial building, and small scale industries. The system is user friendly with includes all standard to ensure ease for use and high reliability.
  • Special Features
  • Tech Specifications
  • Downloads
  • Certificates
  • Tools
    • Switched Mode Power Supply.
    • Modular Construction
    • Auto Resettable Fuse
    • Surge Protection for all Input and outputs.
    • Programmable AC loss delay/Trouble Remainder/Alarm Verification
    • Battery polarity reversible protection
    • Surface Mount Technology
    • Over All current consumption is low.
    • Fully complies with UL -864 and NFPA-72.
    • Rugged CRCA sheet with powder coated finish.
    • Operates on 110 – 220v 50 /60 Hz, AC Mains power supply.
    • 16×2 Dot Matrix LCD Display.
    • 4/8 Class B Style ‘B ‘ or Style ’C’ initiating device circuit (IDC).
      • All zones accept smoke detectors and any normally open contact device.
      • Any Zone can be configured as Alarm or supervisory Zone.
    • 2ClassBNotificationApplianceCircuits(NAC).
    • NAC shall be programmed as silenceable or Non Silenceable.
    • Supervisory Zone shall be Latching or Resettable.
    • Standby (battery) backup 24v DC power supply with built in charger
    • Error free Fire / Fault status in unambiguous colored LED indication.
    • System ON indication.
    • Main, Standby status audible and visual indication.
    • Battery Low visual warning with audible tone.
    • FormC relays for fire, fault and supervisory.
    • Resettable / Steady 24V D.C. Output.
    • RS 485 Communication facility (Optional).
    • Lamp Test facility.
    • All field wiring circuits are Power limited except 110 – 220v AC and Battery.
    • All field wiring circuits are supervised.
    • Walk Test facility.
    • Zone Isolation facility with loop voltage cut off.
    • Earth fault annunciation facility at 0 ohms.
    • AC Low voltage cutoff.
    • Programmable AC loss delay / Alarm verification / Trouble reminder.
  • Electrical Specification

    Primary Power
    120 – 220VAC ± 10%, 50 Hz, 2.5Amps.

    Standby Power
    24V D.C (2 Nos of 12v, 12Ah Sealed Lead acid battery).
    Quiescent current: 120mA

    Initiating Device Circuits
    All zones are Class B Style B/C operation (Programmable).
    Normal Operating Voltage: 14 – 21 VDC.
    Alarm Current: 15 – 30mA.
    Short Circuit Current: 45mA Maximum.
    Loop resistance: 100 ohms Maximum.
    End-Of-Line Resistor: 3K9, 1/2watt
    Standby Current: 7mA (2mA for Detectors)
    Operating Condition
    Operating Temperature 0 – 49° C/32-120° F.
    Relative Humidity 93 ± 2% RH (non- condensing) at 32 ±2° C/90 ±3° F.
     
    Charging Circuit
    Charging Voltage 28.2V, ±0.5V
    Charging Current 800mA (Max.).
    Notification Appliance Circuits
    Class B Style – Y wiring
    Operating Nominal Voltage: 24VDC
    Special Application Current for all NACs: 1.2Amps (0.6A per circuit)
    Line Drop: 1.8V
    End-Of-Line Resistor: 3K9, 1/2watt
    D.C. Output
    Supervised 24VDC regulated, 300mA Max.
     
    Common Relays
    Type : Form C
    No of Relays : 3
    Relay Contact Rating : 2Amps @ 30 VDC,
    0.5Amps @ 125VAC.
    Power Factor : 1.0
     

    Mechanical Specification

    Dimensions : (440W X 340H X 120D)
    Color : Red / White
    Construction : 18 Gauge (1.22mm) CRCA sheet with powder-coated Finish
    IP Rating : IP50
    Cable Entry : 11xø19mm Knockout in top of the cabinet
    10xø22.25mm Knockout in top of the cabinet

    Ordering Information

    Model Description
    RE- 2558-W 8 Zones
    RE-2558-R 8 Zones

    Note:
    W-White Color,
    R- Red Color

    Compatible Devices

    Models Description
    RE-316S-2L Photoelectric Smoke detector with base.
    RE-316H-2L Heat detector with base.
    RE-316SH-2L Photoelectric & Heat detector with base
    RE-314 Common base for above
    RE-716MR MCP Red
    RE-716MG MCP Green
    RE-716MY MCP Yellow
    RE-24CS Mini Horn
    RE-24SS Sounder cum Strobe
    RE-Monitor 24VDC Output for Monitor Module
    RE-3K9 End Of Line Resistor
    • Data Sheet
    • Instruction Manual

    • UL Certificate

    • Battery Calculator
  • Addressable Fire Alarm System
    • Multi Loop System
      • Panels
      • Detectors
      • Modules
      • Manual Activating Devices
      • Notification Devices
      • Networking Devices
      • Softwares
    • Single Loop Control System
      • Panels
      • Detectors
      • Modules
      • Manual Activating Device
      • Notification Devices
  • Conventional Fire Alarm Systems
    • Panels
    • Detectors
    • Manual Activating Devices
    • Notification Devices
    • Networking Devices
    • Softwares
  • Gas Suppression System
    • Panels
    • Manual Activating Devices
    • Networking Devices
  • PA System or Public Address System
    • Main Consoles
    • Expanders
    • Amplifier for PA System
    • Speakers
  • Fireman Telephone System
    • Main Consoles
    • Fireman Jack
    • Handset
  • Emergency Signage

News & Events

We will be present at intersec Dubai 2024
Visit our stand at Intersec 2024, taking place from 16th to 18th January 2024 at the Dubai World Trade Centre ...
We will be present at intersec saudi arabia
Visit our Stall @ Stall no A36, Hall No.4 \r\n03rd – 05th October 2023 Intersec 2023, Riyadh International Con...

Credentials

credentials

 

Quick Links

  • CO Detector Suppliers | Sounder Cum Strobe | RE 326Series | RE 386-NG | GSM Auto Dailer | Soft connect | Gas Leak Detector | Input / Output Module | Loop Powered Sounder | Multi Sensor Detector | UL Listed Fire Alarm Panels | Fire Alarm System | Notification Devices | Fire Alarm Control Panel | Smoke Alarm Detector | Multi Loop System | Heat Detector | Manual Activating Devices | Conventional Fire System | Beam Detectors | Single Loop Control System | Quality Policy
  • 2025 © Ravel Electronics Pvt. Ltd.,

    Quick Enquiry

    Quick Enquiry