Ravel Electronic PVT LTD Brand Logo Ravel Electronic PVT LTD Brand Logo Ravel Electronic PVT LTD Brand Logo
Toll Free No : 1800 1200 72835  +91 44 4204 0204  sales@ravelfire.com
Navigation
  • Home
  • About Us
  • Products
    • Addressable System
      • Multi Loop System
      • Single Loop Control System
    • Conventional Fire Systems
      • Panels
      • Detectors
      • Manual Activating Devices
      • Notification Devices
      • Networking Devices
      • Softwares
    • Gas Suppression System
      • Panels
      • Manual Activating Devices
      • Networking Devices
    • Public Address System
      • Main Consoles
      • Expanders
      • Amplifier for PA System
      • Speakers
    • Fireman Telephone System
      • Main Consoles
      • Fireman Jack
      • Handset
  • Tech Support
    • Escalation Matrix
  • Downloads
    • Datasheet
    • Credentials
    • Certifications
  • Media
    • Press Release
    • Blogs
    • News
  • Career
  • Contact

Eazy beam DS

Home Products Conventional Fire Alarm Systems Detectors Eazy beam DS

Product Overview
This device can be installed easily and quickly by a single person in single point of wiring & commissioning. It has special feature to compensate automatically for natural building movement to continuously maintaining alignment by building movement tracking technology.

Salient Features

  • Auto alignment
  • Easy Installation
  • Standalone Detector

Salient Features

  • Alignment mode switch, alignment directional buttons and configuration switches for alarm response threshold
  • 2 Green LEDs and 1 Yellow LED for alignment status.
  • System status : Green LED flashing every 10 sec in normal condition
                              Red LED flashing every 10 sec in alarm condition
                              Yellow LED flashing every 10 sec for obscuration or every 5 sec for contamination in Fault condition .
  • Flat front face with enclosed optics. Cleaning the optics does not affect alignment.
  • UL Listed.
  • Tech Specifications
  • Downloads
  • Certificates
  • Tools
  • Specifications

    Operating Voltage : 14 to 36 VDC
    Operating current : All operational modes – 5mA; Fast alignment mode – 33mA
    Operating temperature : -20 to +55°C
    Storage temperature : -40 to +85°C
    Relative humidity
    (non-condensing or icing)
    : 0 to 93%
    IP rating : Ip55
    Housing flammability rating : UL94 V0 polycarbonate

    Optical Specifications

    Fault level / Rapid obscuration (Δ ≤ 2 seconds) : ≥85%
    Maximum angular misalignment of Reflective Detector : ±0.5°
    Maximum angular misalignment of Reflector : ±5°
    Maximum angular alignment of Reflective Detector : ±4.5°(±70° with adjustment bracket accessory)

    Detection Performance

    Detection range : 0 to 50m
    0 to 120m with Reflective Long Range Kit
    Alignment method : Laser assisted, Auto-AlignmentTM. Manual alignment – optional setting
    Auto-AlignmentTM protocol : Background check, Box search, Adjust and Centre
    Building Movement TrackingTM : Compensates for natural shifts in alignment from building
    movement*
    Contamination Compensation : Compensates for gradual build-up of contamination on the optical surfaces
    Light Cancellation TechnologyTM  : Compensates for high levels of sunlight and artificial lighting
    Optical wavelength – smoke detection : 850nm near infrared (invisible)
    Integrated laser – laser alignment : 650nm visible. Class IIIa <5mW
    Dynamic Beam Phasing : Allows beam detectors to be mounted facing each other with the
    reflectors in the middle. Eliminates false alarms caused by
    crosstalk between beams
    Signal output : Individual Alarm and Fault relays (VFCO) 2A @ 30 VDC

    Programmable User Settings

    Alarm response threshold levels : 25% (1.25dB) – Fastest response to smoke
    35% (1.87dB) – Default value
    55% (3.46dB) – High immunity to false alarms, slow response to smoke
    85% (8.23dB) – Highest immunity to false alarms, slowest response to smoke. Configured via the integrated user interface
    Delay to Alarm : 10 seconds, for momentary partial obstruction of the beam path
    Delay to Fault : 10 seconds, for momentary obstruction of the beam path

    Design Parameters

    Separation distance between Detector and Reflector : 5 to 50m
    50 to 120m with Reflective Long Range Kit
    Beam path clearance : 1m in diameter from centre line between Detector and Reflector
    Detector dimensions : 130W x 181H x 134D in mm (see diagram)
    Reflector dimensions : Up to 50m separation distance – Single reflector 100mm x 100mm x 9mm Up to 120m separation distance – Four reflectors arranged in a square patter 200mm x 200mm x9mm
    Product weight : Detector – 0.7kg; Reflector – 0.1kg
    Multi-detector arrangement : Dynamic Beam Phasing allows for Detectors to face each other with the reflectors in the middle
    Housing colour : White RAL9016, UV stable

    Field Wiring

    Cable gauge and type : 2 core, dedicated, 0.5 to 1.6mm (24 to 14 AWG)
    System compatible with fireproof and non-fireproof cable meeting local
    installation standards
    Cable entry : 3 knock-out locations capable of accepting M20, 1⁄2″ or 3⁄4″ glands
      : 4 drill-out locations capable of accepting glands up to 21mm diameter

    Test And Maintenance

    Alarm test : Optical alarm test using Commissioning and Maintenance Kit accessory

    Ordering information

    Model No Part No Description
    EazyBeam R60-024-1547 Beam Detector – 50Mtrs
    EazyBeam R60-024-1560 Beam Detector – 120Mtrs
    • Data Sheet
  • Addressable Fire Alarm System
    • Multi Loop System
      • Panels
      • Detectors
      • Modules
      • Manual Activating Devices
      • Notification Devices
      • Networking Devices
      • Softwares
    • Single Loop Control System
      • Panels
      • Detectors
      • Modules
      • Manual Activating Device
      • Notification Devices
  • Conventional Fire Alarm Systems
    • Panels
    • Detectors
    • Manual Activating Devices
    • Notification Devices
    • Networking Devices
    • Softwares
  • Gas Suppression System
    • Panels
    • Manual Activating Devices
    • Networking Devices
  • PA System or Public Address System
    • Main Consoles
    • Expanders
    • Amplifier for PA System
    • Speakers
  • Fireman Telephone System
    • Main Consoles
    • Fireman Jack
    • Handset
  • Emergency Signage

News & Events

We will be present at intersec Dubai 2024
Visit our stand at Intersec 2024, taking place from 16th to 18th January 2024 at the Dubai World Trade Centre ...
We will be present at intersec saudi arabia
Visit our Stall @ Stall no A36, Hall No.4 \r\n03rd – 05th October 2023 Intersec 2023, Riyadh International Con...

Credentials

credentials

 

Quick Links

  • CO Detector Suppliers | Sounder Cum Strobe | RE 326Series | RE 386-NG | GSM Auto Dailer | Soft connect | Gas Leak Detector | Input / Output Module | Loop Powered Sounder | Multi Sensor Detector | UL Listed Fire Alarm Panels | Fire Alarm System | Notification Devices | Fire Alarm Control Panel | Smoke Alarm Detector | Multi Loop System | Heat Detector | Manual Activating Devices | Conventional Fire System | Beam Detectors | Single Loop Control System | Quality Policy
  • 2025 © Ravel Electronics Pvt. Ltd.,

    Quick Enquiry

    Quick Enquiry