RE-102R / 104 R
Overview
-
The RE-102R & RE-104R is a 2 & 4 Zone Fire Alarm Control Panel, which uses conventional input devices. The Outputs include Notification Appliance Circuits (sounders), two programmable Form – C relays, RS-485 port to interface with annunciators and optional zone wise sounder & zone wise contact. The FACP is field programmable via the panel keypad. It also supervises all wiring, AC voltage and battery level. Optional ethernet, & GSM ports are user for transmission
- This Fire Alarm Control panel is designed to be used for small size commercial buildings and small-scale industries.
-
- CE Approved.
- 16 X 2 Dot Matrix LCD Display.
- Standby battery backup with built in charging.
- Switch Mode Power Supply.
- Tactile Keypad for easy panel operation.
- System ON indication.
- Low Battery visual warning with audible tone.
- Fire / Fault status in unambiguous colored LED indication.
- 2 programmable relays for fire, supervisory and fault.
- All zones accept smoke detectors and any normally open contact device.
- Any Zone can be configured as alarm or supervisory.
- Zone wise isolation and one man walk test facility.
- Programmable Aux Outputs.
- Lamp test & Drill test facility.
- 100 All Events log with RTC.
- Date / Time / Password configuration.
- Programmable auto silence facility.
- Zone wise sounder / contact (optional).
- TCP-IP / GSM facility (optional).
- All field wiring circuits are supervised.
-
Electrical Specification
Primary Power
120 / 230VAC + 10% -15%, 60 / 50 Hz, 50WStandby Power
24VDC (2 Nos of 12V, 3.5Ah Sealed Lead acid battery)
Quiescent current : 55mAOperating Condition
Operating Temperature 0 – 49° C / 32 – 120° F.
Storage Temperature 0 – 60° C
Relative Humidity 93 ± 2% RH (non-condensing) at 32 ± 2° C / 90 ± 3° FQuiescent Current
2 Zone
4 zone40mA
50mACharging Circuit
Charging voltage
Charging current28 V ± 5%
350mA (max)24VDC
Quantity
Voltage
Current1 No
24VDC continuous or resettable (Regulated)
100mA (max)Notification Appliance Circuits
Wiring style
Quantity
Operating voltage
Current
EOL resistorClass B
1 No
24VDC (Regulated)
350mA
4K7, 1/2 wattRelays
Type
Quantity
Relay contact rating
Power factorForm C
2 No’s (Programmable)
1A @ 30 VDC
1.0Initiating Device Circuits
Wiring style
Quantity
Normal operating voltage
Alarm current
Short circuit current
Loop resistance
EOL Resistor
Standby CurrentClass B
2 or 4 (102R- 104R)
14 – 21 VDC
15 – 35 mA
42 mA (max)
50 Ω (max)
4K7, ½ watt
6.8 mA (2.4 mA for detectors)RS 485
Nodes
Wiring Style
Wire type
Circuit Length
Loop resistance1
Class B
Twisted pair
1.2 Km (Max)
100 OhmsMechanical Specification
Dimensions : 300L X 200W X 95D Wire Size : 1.5 Sq mm IP rating : IP 60 Color : Black Material : FRABS plastic Cable Entry : 11 x ø19mm Knockout on top of the cabinet Ordering Information
Model Description RE-102R 2 Zone Fire Alarm Panel RE-104R 4 Zone Fire Alarm Panel Compatible Devices
Model Description RE-316S-2L Photoelectric Smoke detector with base. RE-316H-2L Heat detector with base. RE-316SH-2L Photoelectric & Heat detector with base RE-716 MR Conventional Manual Call Point. RE-716P1T Manual Pull station – Single action. RE-716P1TLP (R) Manual Pull station – Dual action. RE-25SS Conventional Sounder cum Strobe RE- 24 CS Conventional Sounder. RE-716SO Conventional Sounder – UL Listed. RE-716SO Conventional Sounder cum Strobe – UL Listed. RE-364BS Conventional Sounder Base. -